System technology

JUMO mTRON T - Central Processing Unit (705001)

• Process mapping for up to 30 input/output modules

• Ethernet interface with integrated Web server

• 1 USB interface

• 64 limit values are monitored

                                             • PLC according to IEC 61131-3 (option)

                                             • OPC server (in connection with PLC)

                                             • 9 program generators (option)

                                             • 2 field bus interfaces (option)

                                             • Math and logic module

                                               (optional, activation for all connected controller modules)

                                             • RJ45 system bus connection on front (Bus Out)

                                             • Plug and Play for input/output module replacement

                                             • Battery-buffered RAM

                                             • Real-time clock

                                             • Robust metal case

                                             • Supply of operating voltage

                                             • Quick wiring of operating voltage and system bus provided by simple

                                               module connection principle

                                             • Data sheet : EN 

JUMO mTRON T - Multichannel Controller Module (705010)

• Up to four PID controller channels, each with two parameter sets and

  four setpoint   values

• Self-optimization with the oscillation or step response method

• Independent operation

• Two high-quality universal analog inputs for thermocouple, RTD

  temperature probe , resistance transmitter, resistance/potentiometer,

  and standard signals

• Customer-specific linearization (up to 4th order polynomial)

• Two digital inputs DC 0/24 V

• Two digital outputs as relays with normally open contact AC 230 V/3 A

                                               or logic DC 0/15 V

                                             • Inputs and outputs can be extended (option)

                                             • All analog inputs are galvanically isolated from each other

                                             • Limit value monitoring

                                             • One counter input up to 10 kHz

                                             • Automatic configuration after module insert replacement

                                             • Connection of inputs and outputs on front

                                             • Removable terminal strips with Push-In technology

                                             • Quick wiring of operating voltage and system bus provided by simple

                                               module connection principle

                                             • Data sheet : EN 

JUMO mTRON T - Relay Module 4-Channel (705015)

• Four relay outputs with changeover contact AC 230 V/3 A   

• Automatic configuration after module insert replacement

  (Plug and Play)

• Connection of outputs on front

• Removable terminal strips with Push-In technology

• Quick wiring of operating voltage and system bus provided by simple

  module connection principle

• Data sheet : EN                                                                        

 

 

JUMO mTRON T - Analog Input Module, 4-Channel (705020)

• Four high-quality universal analog inputs for thermocouple, RTD

  temperature probe, resistance transmitter, resistance/potentiometer,

  and standard signals

• All analog inputs are galvanically isolated from each other

• Customer-specific linearization

  (up to 45 pairs of values or 4th order polynomial) 

• Limit value monitoring

• 1 DC 0/24 V digital input

• Automatic configuration after module insert replacement

  (Plug and Play) 

                                      • Connection of inputs on front

                                      • Removable terminal strips with Push-In technology

                                      • Quick wiring of operating voltage and system bus provided by simple

                                        module connection principle

                                      • Data sheet : EN 

JUMO mTRON T - Analog Input Module, 8-Channel (705021)

• Eight analog inputs for RTD temperature probes in 2-wire circuit

• Limit value monitoring

• 1 DC 0/24 V digital input

• Automatic configuration after module insert replacement

  (Plug and Play) 

• Connection of inputs on front

• Removable terminal strips with Push-In technology

• Quick wiring of operating voltage and system bus provided by simple

  module connection principle

• Data sheet : EN  

 JUMO mTRON T Analog Output Module 4-channel (705025)

• Four analog outputs 0(2) to 10 V or 0(4) to 20 mA

  (configurable per channel)

• Configurable behavior in case of an error, e.g. acc. to NAMUR  

   recommendation NE 43

• Automatic configuration after the module insert has been exchanged

  (hot swappable)

• Connection of outputs on front

• Removable terminal strips with Push-In technology

• Quick wiring of operating voltage and system bus provided by simple

  module connection principle

                                             • Data sheet : EN 

JUMO mTRON T - Router Module (705040)

• RJ45 system bus connections on front (1 × Bus In, 2 × Bus Out)

• Decentralized module assignment supported

• Addressing via rotary coding switch for special applications

• Galvanic isolation of interfaces on front

• Supply of operating voltage

• Quick wiring of operating voltage and system bus provided by simple

  module connection principle

• Data sheet : EN  

 

 

JUMO mTRON T - Multifunction Panel 840 (705060)

• 21.3 cm (8.4") TFT touchscreen with a resolution of 640 × 480 pixels

  and 256 colors

• Pre-defined screen masks for controller, program generator, and

  Recording function

                                            • Customer-specific process screens

                                            • User administration

                                            • Configuration access to the overall system

                                            • Recording function (option)

                                            • Integrated Web server

                                            • Ethernet interface

                                            • Three USB interfaces

                                            • Two RJ45 system bus connections (1 × Bus In, 1 × Bus Out)

                                            • Two serial interfaces (option) as RS232 or RS422/485 for barcode

                                              scanner and Modbus RTU master/slave

                                            • Robust metal case, IP67 protection on front

                                            • Data sheet : EN 

JUMO mTRON T - Power Supply Units (705090)

• AC 100 to 240 V wide-range input

• Quick-connect spring-clamp terminals

• Robust metal case

• Up to 93.5 % efficiency

• Active power factor correction (PFC)

• 150 % peak load capability

• Data sheet : EN